warning
In 2 minutes you will be logged out due to inactivity.
For information regarding change log and version number methodology, please click
here.
This release solely adds support for a new component on the circuit boards of the touchscreen models. This firmware is backwards compatible with old revisions of the circuit board but offer no user-facing functional enhancements.
Description |
Impact |
Recommendation |
Support for Component Replacements
- Added backwards compatible support for new flash memory chip
- Updated bootloader to support new flash chip
|
No impact |
No testing needed |
Description |
Impact |
Recommendation |
Enhancements
- Updated SSL Cipher Suite
- Implement Additional Differential Pressure Units
- Audible Calibration Alarm was replaced with a calibration alarm pop up
- Downloading data from TSB using DicksonWare 2.0 with USB cable
- Add Sensor Port to Readings Packet
- Added backup settings to prevent devices from resetting their own settings
|
Low impact |
No testing needed |
Bugs
- Enterprise Connection attempts Authentication with Username GSN
- Alarms triggered at alarm set value
- Sensor swaps caused device reboot
- Logger would not report model SKU to DicksonOne
- Calibration warnings on the device displayed the wrong port number
- Clearing the Min/Max with a probe error caused high Min/Max values
- Device does not boot up from a low power state
- Parse Incoming Proxy Settings through API
- New channels are not created properly when swapping different sensor models
- Device does not send readings packets while still sending ping and configuration packets
- Units lock up and reboot
|
Minor impact |
Check new functionality |
Description |
Impact |
Recommendation |
- BSSID to be included in API logs
- Option to export Partial (Since Last Export) or all Historical Data (Entire History) have been added
- USB icon flashes on the display when taking a screenshot
- Min/Max has been added to the Text Display View
- A button to reset the Min and Max has been added
- Viewable characters have been expanded for the device name on the screen
- Dallas/Sensiron Pod Replacement to improve sensor swapping
- Connection improvement has made to adhere to Access Point hopping based on RSSI values
- WiFi Scan List has been improved to display more SSIDs
- Thread IDs are now reset properly when performing a factory reset on the device
- The label for Device Code has been renamed to Registration Code to mirror DicksonOne
|
No impact |
No testing needed |
Description |
Impact |
Recommendation |
- Adjust real-time clock’s offset to account for drift (mainly for TSBs or TWE/TWPs used without DicksonOne)
- Changed default sample rate to 5 minutes instead of 1 minute
|
No impact |
No testing needed |
- Resolved bug where battery may be drained too quickly.
- Resolved bug where USB exports attributed readings to the incorrect serial number
|
Low impact |
No testing needed |
This update is required for continued operation of your TWE/TWP after October 12, 2018.
Description |
Impact |
Recommendation |
This is the same as the pervious version (2.4.27) but has the new security certificates to address Google’s decision to distrust some existing certificates.
|
No impact |
No testing needed |
Description |
Impact |
Recommendation |
- Patch for graph plotting and USB data export
- Update to Ping/Config Packet interval during catch-up
- Patch for Proxy over Ethernet with HTTPS functionality
- General improvements to Ethernet communication (non-proxy)
- Add ping packet button popups
- Implement differential pressure functionality
- Update for displaying differential pressure data on display and USB export
- Adjustment to the humidity min/max custom setting button
- Update to differential pressure .csv export to display data up to 3 decimal places
- Update to diff pressure .loj export to enable data up to 3 decimal places
- Data export to Flash drive (Differential Pressure)
- Implement validation to verify a block is empty and available for immediate use
- Enable backwards compatibility with 2.1.4 (Current Production Version)
|
No impact |
No testing needed |
Description |
Impact |
Recommendation |
-
Fixed issue causing extended decimal places in readings.
-
Changed network layer to prioritize sending readings.
-
Added additional logging to ping packet.
-
Increased watchdog timeout for network layer.
-
BSSID and SSID now included in debug information.
-
SSID and DHCP now included in network settings packet.
-
Detection of board revision and updated power control logic.
-
Reduced packet frequencies of ping and config. Added button on network settings
page to send a ping packet.
-
Removed block on having multiple multi-channel pods attached.
-
Fix for connection to WEP networks.
-
Fixed bug in data export of dicksonware file.
|
No impact |
No testing needed |
Description |
Impact |
Recommendation |
- Changed wifi connection logic to scan and choose best bssid when connecting.
- Fixed bug causing screen to not display when booting from low power mode.
- Changed labels on information screen from Pod to RS.
- Added reset of LCD peripheral to address white screen issue.
|
No impact |
No testing needed |
Description |
Impact |
Recommendation |
-
Fixed issue with debug printing causing crashing when usb stick plugged in.
-
Increased readings timeout to work with thermocouple pods.
-
Fixed issue with graph scale not being saved to settings.
|
No impact |
No testing needed |
Description |
Impact |
Recommendation |
- Fixed low memory issue related to new ssl certificate
|
No impact |
No testing needed |